TOKAI HIT KRi Sample Temperature Feedback Cooling & Heating Stage Top Incubator with Gas Flow Meter for Premixed Gas INUCP-KRi-F1 |
|
TOKAI HIT INUCP-KRi-F1 Cooling & Heating Stage Top Incubator with Sample Feedback Control handles a wide range of samples, cell culture, plants, fish etc. The INUCP-KRi-F1 is designed to provide heating, cooling and pre mixed gas to the environmental stage top chamber. The Sample Feedback Control provides stability against temperature changes and maintains optimal temperature of the chamber environment at all times. The INUCP-KRi-F1 is designed for inverted Olympus, Nikon, Leica and Zeiss Microscopes and can be used on motorized or manual stages.
|
|
Features: |
- For use with inverted microscopes
- Preset specimen temperature range 20°-40°
Long Working Distance / Dry lens: 15°-40°
Short Working Distance, oil/water immersion lens: 20°-40°
- Sample Temperature Feedback Control(Pat.P)
1.Allows precise specimen temperature adjustment. Possible to adjust sample temperature close to ambient. This system has both cooling and heating function and by automatically shifting the function, it allows stable and smooth ambient temperature control. NOTE: Under room temperature of 25.0 degree C ±2.0 degree C.
2.Determines optimal Stage Heater temperature Setting Value for room temperature during preliminary operation and incubates sample without inserting Sensor into a dish during operation.
3.Neco's exclusive software outputs sample temperature to PC.
- Wide range of applicable dishes
|
|
Temperature & Gas Management Software |
Neco enables user to control and record the sample & chamber environmental temperature during time-lapse.
Temperature & Gas management
Neco allows to adjust temperature and gas concentration by PC.
Real time monitoring and logging
Display and record real time temperature and CO2.
Sampling data is saved in CSV file
Display channels
6 channels for temperature 2 channels for gas (CO2 & O2).
NOTE: To change, monitor and log gas concentration rate via PC, GM-4000A/E or GM-8000 are required with Neco System.
PC operating system requirement :Windows 7 / Vista (32/64bit) Windows XP SP2 / SP3 |
Interface:RS-232C |
|
|
Ideal for TIRF |
- Optimal for time-lapse fluorescence observation on the level of 1 molecule.
- System keeps focus drift to a minimum from TIRF time-lapse imaging.
- Corresponds to TIRF objective 60x -100x
|
|
Uniform Temperature Distribution |
Provides uniform temperature distribution during Heating & Cooling
NOTE: 35mm dish with 2ml water |
Heating 37 ° |
Cooling 20° |
|
Sample Temperature Feedback Control |
With Sample Feedback Control, temerature is stable against external or internal temperature changes and keeps optimal temperature at all times.
NOTE: 35mm dish with 3ml water |
|
|
|
Order Information: |
|
|
Model # |
Description |
INUCP-KRi-F1 |
KRi Cooling & Heating Stage Top Incubator With a gas flow meter for premixed gas. |
|
|
|
|
Options |
|
|
Dish Attachments |
Model # |
Description |
KRiH-D35 |
Dish Attachment
Heating only for 35mm dish |
KRi-D35 |
Dish Attachment Heating & Cooling for 35mm dish |
KRiH-D35-2 |
Dish Attachment
Heating only for 35mm dish x 2pc |
KRi-D35-2 |
Dish Attachment Heating & Cooling for 35mm dish x 2pc |
KRiH-D56 |
Dish Attachment
Heating only for 50/60mm dish |
KRi-D56 |
Dish Attachment Heating & Cooling for 50/60mm dish |
KRiH-SC |
Dish Attachment
Heating only for chamber slide and slide glass |
KRi-SC |
Dish Attachment Heating & Cooling for chamber slide and slide glass |
|
NOTE: |
1.One of Dish Attachment is included as standard feature.
Select one from Cooling/Heating Dish Attachment line.
2.Cooling/Heating Dish Attachment has 22mm diameter opening
for cooling effect and it has a heat insulating material at bottom.
3.Heating only Dish Attachment has 28mm diameter opening. |
|
|
|
Stage Adapters |
Model # |
Description |
MK-RA |
Stage Adapter for manual stage with round opening For cross stage, rectangular stage |
|
|
Sensor Lids |
Model # |
Description |
D35-200F |
Sensor Lid for 35mm dish (with a sterilizable Feedback Sensor) |
D56-200F |
Sensor Lid for 50/60mm dish (with a sterilizable Feedback Sensor) |
CS-200F |
Sensor Lid for chamber slide (with a sterilizable Feedback Sensor) |
CGC-200F |
Sensor Lid for chambered cover glass (with a sterilizable Feedback Sensor) |
TSU-200F |
Temperature Feedback Sensor (300mm) |
HD1500 |
Lead line(1500mm) |
|
|
|
|
|
|
|
|
|