    Ocean Optics RaySphere Solar Analysis System

    The New RaySphere Solar Analysis System for absolute irradiance measurements of solar simulators and other radiant sources. The new RaySphere from Ocean Optics measures absolute irradiance over spectral ranges from the UV to the
    NIR (350 to 1700 nm).

    This portable system is ideal for solar simulator manufacturers and research and development labs as a tool to validate the output of installed solar flashlamps. The flash of a solar simulator is used within the photovoltaic (PV) manufacturing
    process for the binning of cells according to spectral response and for final PV module efficiency measurements.

    The RaySphere system delivers the accuracy and resolution needed to measure and analyze the performance and stability of the flasher with ultralow jitter triggering electronics for timing the measurement to the flashes. Calibration has been validated by an accredited certification lab to ensure accurate detection, enabling evaluation and qualification of the spectral distribution of solar flashers and simulators according to the
    IEC 60904-9 (2007) standard.

    The system includes two thermoelectrically cooled detectors that perform repeatable and accurate spectral analysis of solar flashers from 350 to 1700 nm. A second version contains a single cooled detector for measurement to 1100 nm.

    Features:
    • Intuitive graphical interface
    • Graphical and table display of classification results by wavelength bin
    • Output of actual spectra in mW/cm^2/nm
    • Output of actual measurement and triggering timing with +/- 41 μs resolution
    • Printable classification report
    • Three Year Warranty

    Spceifications:
      RaySphere RaySphere 1700
    Spectral Range: 350-1100 nm 300-1700 nm
    Spectral resoluton:

    1.9 nm (FWHM) for 300 - 1100 nm
    12.5 nm (FWHM) for 1100-1700 nm

    Optical input:

    50 mm integrating sphere

    Detector types: TEC stabilized Hamamatsu CCD sensor TEC stabilized Hamamatsu InGaAs sensor
    Dynamic range:

    25000:1 (Back-thinned Si)
    15000:1 (InGaAs)

    Corrected linearity:

    >99.8%

    Minimum integration time:

    8 ms

    Calibration:

    Calibrated for irradiance measurements using national traceable standards (NIST, PTB, CNIM)

    Calibration Accuracy:

    Validated by accredited certification institute, typical values better than 2% accuracy in 400-1100 nm range

    Triggering options:

    Built-in photo trigger, external trigger, manual trigger

    Operating environment:

    Built-in photo trigger, external trigger, manual trigger

    Software:

    Custom Analysis Software for Windows XP, Vista and 7 (32 and 64 bit)

    Communications:

    USB 2.0 high-speed

    Photo-Trigger Specifications:
    Jitter (Realtime): <100 ns
    Jitter (Software displayed): 164 µs
    Minimum measurement time: ~9 ms
    Programmable trigger delay: 1040 µs - 168 ms
    Trigger delay increment: 2.56 µs
    Time resolution of display: +/- 41 µs