Home > Stages > Heating Stages > Linkam Heating Stages > Linkam Examina Vacuum System


Linkam Examina Vacuum System
Linkam Examina Vacuum System with Cooling Option
Linkam Examina Vacuum System

Features and Benefits:

Based upon the proven low pressure and temperature control technology developed for the Freeze Drying System (FDCS196), Linkam has modified the stage body and temperature control element to extend the temperature range from -196°C up to 350°C at a vacuum of 10-3mbar using a simple 1.5L rotary vacuum pump.

It is now possible to carry out ultra low temperature experiments with virtually no gas or air contamination of the sample. By substituting a vacuum port for a gas valve it is also possible to first pull a vacuum and then bleed in the desired gas.

A prirani gauge can be supplied to relay the sample chamber pressure to either the Linksys 32 software or the display panel on the TMS94 temperature programmer.

By connecting the vacuum pump to the MV196 motorized valve, pressure can be quickly and accurately varied utilizing simple on screen software controls.

The temperature is programmed by the standalone TMS94 temperature programmer. Sophisticated temperature profiles of up to 32 ramps can be set up with ranges of heating rates from 0.1C/min to 30C/min.

The TMS94 can be used as a standalone programmer or connected via RS232 to PC enabling use of further features within the Linksys 32 software.

TMS94 firmware can be updated via email using the RS232 connection.


Specifications: Click Here for a PDF About Linkam's Examina Pressure System

  • Temperature Range -196°C to 350 °C
  • 16 mm X,Y sample manipulation
  • Sample area of 22mm diameter
  • No PC required (unless using motorized valve)
  • Vacuum tested to 10-3mbar
  • Can be used with transmitted or reflected light
  • Mounts directly to microscope table or substage
  • Stage body size - 160 x 80 x 24 mm
  • 100 ohm platinum sensor 1/10th din standard class A
  • Temperature stability < 0.1°C
  • Direct injection of coolant into block
  • Highly conductive metal for improved heat transfer
  • Maximum heating / cooling rate of 30°C/min
  • Response time of <1 second at 5°C/min at 50°C
  • Objective lens minimum working distance 4.5mm
  • Condenser lens minimum working distance 13.2

Examina Vacuum System Includes:

  • THMS350V vacuum stage
  • T95-LinkPad Controller and vacuum gauge

    All necessary cables

    OPTIONAL EXTRAS
    *Cooling option required to extend range to -196°C
    THMS-LNP95 automated liquid nitrogen cooling System


<<< Go Back



Spectra carries a wide variety of stages. Select from one of the manufacturers below to find what you need.
 
2020 Technology Stages linkam Systems and StagesInstec hot and Cold Stages
 

The THMS350V heating and freezing stage

The THMS350V heating and freezing stage
Temperature Range -196 to 350°C

Linkam Examina Vacuum Stage with Vacuum Gauge attached

Examina Vacuum Stage with Vacuum Gauge attached.

 


Request a quote!
Spectra Services Downloads
New Lab Startup Work Sheet
Home | About Spectra Services | Contact Us | FAQ | Testimonials |
Services | Application Info | International Shipping
| Used Equipment
Spectra Home

© 2010 Spectra Services